Rosemount 1153 Series D
Load Effect
No load effect other than the change in the voltage supply to the transmitter
Mounting Position Effect
No span effect; zero shift of up to 1.5 inH
2
O (372 Pa) which can be calibrated
out
Response Time
Fixed time constant (63%) at 100 °F (37.8 °C) as follows:
Adjustable damping is available through a special N-Option.
Range Code Response Time
3 2 seconds or less
4 0.5 seconds or less