Emerson Process Management 1153 SERIES D Marine Radio User Manual


 
Reference Manual
00809-0100-4388, Rev BA
January 2008
Rosemount 1153 Series D
6-6
FUNCTIONAL
SPECIFICATIONS
Service
Liquid, gas, or vapor
Output
4–20 mA dc
Power Supply
Load limits are as shown in Figure 6-2
Figure 6-2. Load Limits. Transmitter Load Limits
Output Code P
Output Code R
Span and Zero
Continually adjustable externally
Zero Elevation and Suppression
Maximum zero elevation: 600% of calibrated span
(400% of calibrated span for Range Code 0)
Maximum zero suppression: 500% of calibrated span (300% of calibrated
span for Range Code 0)
Zero elevation and suppression must be such that neither the calibrated span
nor the upper or lower range value exceeds 100% of the upper range limit.
4—20 mA DC
Design
Region
Qualified
Region
2000
1650
1325
1500
1000
500
0
0
12
13.5
30
40
45
Power Supply (V DC)
Load Resistance (Ω)
4—20 mA DC
Design
Region
Qualified
Region
1825
1575
1500
1000
500
0
0
12
13.5
35
40
45
50
Power Supply (V DC)
Load Resistance (Ω)