Table 6-1. Transmitter Design Specifications.
Model Product Description
1153 Alphaline Pressure Transmitters for Nuclear Applications
Code Pressure Measurement
D
H
A
G
Differential Pressure; 2,000 psig (13.8 MPa) Static Pressure Rating
Differential Pressure; 3,000 psig (20.68 MPa) Static Pressure Rating
Absolute Pressure
Gage Pressure
Code Series
D SST Housing; qualified per IEEE Std 323-1974 and IEEE Std 344-1975
Code
Pressure Ranges at 68 °F
Rosemount 1153D
(Differential)
Rosemount 1153H
(Differential)
Rosemount 1153A
(Absolute)
Rosemount 1153G (Gage)
3 0–5 to 0–30 inH
2
O
(0–1.24 to 0–7.46 kPa)
N/A N/A 0–5 to 0–30 inH
2
O
(0–1.24 to 0–7.46 kPa)
4 0–25 to 0–150 inH
2
O
(0–6.22 to 0–37.3 kPa)
0–25 to 0–150 inH
2
O
(0–6.22 to 0–37.3 kPa)
N/A 0–25 to 0–150 inH
2
O
(0–6.22 to 0–37.3 kPa)
5 0–125 to 0–750 inH
2
O
(0–31.08 to 0–186.4 kPa)
0–125 to 0–750 inH
2
O
(0–31.08 to 0–186.4 kPa)
0–125 to 0–750 inH
2
O
(0–31.08 to 0–186.4 kPa)
0–125 to 0–750 inH
2
O
(0–31.08 to 0–186.4 kPa)
6 0–17 to 0–100 psi
(0–0.12 to 0–0.69 MPa)
0–17 to 0–100 psi
(0–0.12 to 0–0.69 MPa)
0–17 to 0–100 psia
(0–0.12 to 0–0.69 MPa)
0–17 to 0–100 psi
(0–0.12 to 0–0.69 MPa)
7 0–50 to 0–300 psi
(0–0.34 to 0–2.07 MPa)
0–50 to 0–300 psi
(0–0.34 to 0–2.07 MPa)
0–50 to 0–300 psia
(0–0.34 to 0–2.07 MPa)
0–50 to 0–300 psi
(0–0.34 to 0–2.07 MPa)
8 0–170 to 0–1,000 psi
(0–1.17 to 0–6.89 MPa)
N/A 0–170 to 0–1,000 psia
(0–1.17 to 0–6.89 MPa)
0–170 to 0–1,000 psi
(0–1.17 to 0–6.89 MPa)
9 N/A N/A N/A 0–500 to 0–3,000 psi
(0–3.45 to 0–20.68 MPa)
0 N/A N/A N/A 0–1,000 to 0–4,000 psi
(0–6.89 to 0–27.56 MPa)
Code Output
P
R
(1)
(1) The Rosemount 1153 Series D with the Output Code R Electronics is also available with adjustable damping. Specify
this option by adding “N0037” to the end of the complete model number. For example: 1153DD4RAN0037.
Standard 4–20 mA
Improved Radiation Performance, 4–20 mA
Code Flange Option
A
B
(2)
C
(2)
D
E
(2)
F
(2)
G
H
J
(2)
L
M
(2)
(2) Customer assumes responsibility for qualifying interfaces on this option. Contact Rosemount Nuclear Instruments, Inc.
for details.
Welded
3
/8-in. Swagelok Compression Fitting Process Connection and Welded Drain/Vent Valve
1
/4–18 NPT Process Connection and Welded Drain/Vent Valve
1
/4–18 NPT Process Connection and Drain Hole (Drain/Vent Valve Not Included)
One Flange Option Code A and one Remote Seal
One Flange Option Code B and one Remote Seal
One Flange Option Code C and one Remote Seal
Two Remote Seals
Welded
3
/8-in. Swagelok Compression Fitting on Process Connection and Drain/Vent Connection
Welded
3
/8-in. Swagelok Compression Fitting Process Connection and
1
/4–18 NPT Drain Hole
One Flange Option Code H and one Remote Seal
One Flange Option Code J and one Remote Seal
Typical Model Number:1153 D D 4 R A