Emerson Process Management 1153 SERIES D Marine Radio User Manual


 
Reference Manual
00809-0100-4388, Rev BA
January 2008
6-7
Rosemount 1153 Series D
Temperature Limits
Normal operating limits: 40 to 200 °F (4.4 to 93.3 °C)
Qualified storage limits: –40 to 120 °F (–40 to 48.9 °C)
Humidity Limits
0–100% relative humidity (NEMA 4X)
Volumetric Displacement
Less than 0.01 in
3
(0.16 cm
3
)
Turn-On Time
2 seconds maximum. No warm-up required.
Pressure Ranges
Rosemount 1153DD and 1153HD:
Rosemount 1153GD and 1153AD:
Maximum Working Pressure
Rosemount 1153DD and 1153HD:
Static pressure limit
Rosemount 1153GD and 1153AD:
Upper range limit
Range Code Pressure Ranges
3 0–5 to 0–30 inH
2
O (D units only)
(0–1.24 to 0–7.46 kPa)
4 0–25 to 0–150 inH
2
O
(0–6.22 to 0–37.3 kPa)
5 0–125 to 0–750 inH
2
O
(0–31.08 to 0–186.4 kPa)
6 0–17 to 0–100 psi (0–0.12 to 0–0.69 MPa)
7 0–50 to 0–300 psi (0–0.34 to 0–2.07 MPa)
8 0–170 to 0–1,000 psi (D units only)
(0–1.17 to 0–6.89 MPa)
Range Code Pressure Ranges
3 0–5 to 0–30 inH
2
O (G units only)
(0–1.24 to 0–7.46 kPa)
4 0–25 to 0–150 inH
2
O (G units only)
(0–6.22 to 0–37.3 kPa)
5 0–125 to 0–750 inH
2
O
(0–31.08 to 0–186.4 kPa)
6 0–17 to 0–100 psi (0–0.12 to 0–0.69 MPa)
7 0–50 to 0–300 psi (0–0.34 to 0–2.07 MPa)
8 0–170 to 0–1,000 psi
(0–1.17 to 0–6.89 MPa)
9 0–500 to 0–3,000 psi (G units only)
(0–3.45 to 0–20.68 MPa)
0 0–1,000 to 0–4,000 psi (G units only)
(0–6.89 to 0–27.56 MPa)