Furuno FAR-2107(-BB) Marine RADAR User Manual


 
3. TARGET TRACKING (TT)
3-7
[TT TARGET MENU]
1 TT SELECT
MANUAL100/
AUTO 25/
AUTO 50/
AUTO 75/
AUTO 100
4 ALL CANCEL
NO/YES
3 REF TARGET VECTOR
OFF/ON
3.6 Manual Acquisition
Maximum 100 targets may be acquired manually depending on the acquisition
condition set on the TT TGT menu.
3.6.1 Setting manual acquisition conditions
1. Right-click the arrow in the TT ACQ MODE box at the right side to show the
TT TARGET menu.
TT TARGET menu
2. Select 1 TT SELECT.
3. Select MANUAL 100, AUTO 25, AUTO 50 or AUTO 75 as appropriate. For
details see the table on page 3-5.
4. Push the right button to close the menu.
3.6.2 Manually acquiring targets
By keyboard
1. Put the cursor on the target you want to acquire.
2. Press the [ACQ] key.
By trackball
1. With the cursor inside the effective display area, roll the scrollwheel to show
"TT TARGET DATA & ACQ" in the guidance box.
2. Put the cursor on the target you want to acquire.
3. Push the left button to acquire the target.