Mitsumi electronic fr-a7np e Marine Battery User Manual


 
13
WIRING
3
3.2 Wiring
Use the network connection cable which supports 12.0Mbps communication.
(1) Strip off the sheath of the PROFIBUS communication dedicated cable and wind wires and shield cables
to use. If the length of the sheath pealed is too long, a short circuit may occur among neighboring wires.
If the length is too short, cables and shield cables might come off.
REMARKS
yInformation on blade terminals...recommended product (as of January 2010)
Blade terminal crimping tool: CRIMPFOX 6 (Phoenix Contact Co., Ltd.)
Cable stripping length
Approx 5mm
Wire the stripped cable after twisting it to prevent it from
becoming loose.
(Do not solder it.)
Use a blade terminal as required.
Terminal Screw Size
Cable Size
(mm
2
)
Blade Terminal Model
Manufacturer
With insulation
sleeve
Without insulation
sleeve
M2 0.3 to 0.5 Al 0,5-6WH A 0,5-6
Phoenix Contact
Co.,Ltd.
When using the blade terminal (without insulation sleeve),
use care so that the twisted wires do not come out.