Mitsumi electronic fr-a7np e Marine Battery User Manual


 
54
PPO TYPE SUPPORT SPECIFICATION
7.7 PROFIBUS PNU
7.7.1 Real-time monitor
The following items can be monitored from the master.
*1 Input terminal monitor details
Functions of each terminal are assigned using Pr.178 to Pr.184. (Refer to the inverter manual for details.)
*2 Output terminal monitor details
Functions of each terminal are assigned using Pr.190 to Pr.192. (Refer to the inverter manual for details.)
PNU Item
Increments
Data
Type
P1.1
Output frequency 0.01Hz
AUs16
P1.2
Output current 0.01A
AUs16
P1.3
Output voltage 0.1V
AUs16
P1.5
Frequency setting 0.01Hz
AUs16
P1.7
Motor torque 0.1%
AUs16
P1.8
Converter output voltage 0.1V
AUs16
P1.9
Regenerative brake duty 0.1%
AUs16
P1.10
Electronic thermal relay
function load factor
0.1%
AUs16
P1.11
Output current peak value 0.01A
AUs16
P1.12
Converter output voltage peak
value
0.1V
AUs16
P1.14
Output power 0.01kW
AUs16
P1.15
Input terminal status *1
AUs16
P1.16
Output terminal status *2
AUs16
P1.20
Cumulative energization time 1h
AUs16
P1.23
Actual operation time 1h
AUs16
P1.24
Motor load factor 0.1%
AUs16
P1.25
Cumulative power 1kWh
AUs16
P1.52
PID set point 0.1%
AUs16
P1.53
PID measurement value 0.1%
AUs16
P1.54
PID deviation 0.1%
AUs16
P1.61
Motor thermal load factor 0.1%
AUs16
P1.62
Inverter thermal load factor 0.1%
AUs16
P1.63
Cumulative power 2 0.01kWh
AUs16
PNU Item
Increments
Data
Type
b15 b0
—————RESMRS—RHRMRL——STRSTF
b15 b0
——————————ABCFU———RUN