Mitsumi electronic fr-a7np e Marine Battery User Manual


 
49
PPO TYPE SUPPORT SPECIFICATION
7
ZSW
0 to 2 Not used (1 is returned)
Fault 3
0: Inverter normal
1: Inverter alarm occurrence
4, 5 Not used (1 is returned)
Power-on inhibit 6 0 is returned
Alarm 7
0: Command execution normal
1: Command execution error
8 Not used (0 is returned)
Control request 9 1 is returned
Output frequency
detection
(FU signal)
10
0: OFF
1: ON (output frequency being detected) (For details, refer to Pr. 42 and
Pr.43 in the inverter manual.)
Inverter running
(RUN signal)
11
0: OFF
1: ON (inverter running)
Forward running 12
0: Other than forward running (during stop, reverse running)
1: Forward running
Reverse running 13
0: Other than reverse running (during stop, forward running)
1: Reverse running
NET mode 14
0: Other than network operation mode
1: Network operation mode
Name Bit Definition