PPO TYPE SUPPORT SPECIFICATION
7
ECW
High speed operation
command
(Terminal RH function)
0
Functions assigned to terminal RH, RM, RL are activated.
(Signal names are initial values. Using Pr.180 to Pr.182, you can change
output signal functions.
Refer to the inverter manual for details of Pr.180 to Pr.182.)
Middle-speed
operation command
(Terminal RM function)
1
Low-speed operation
command
(Terminal RL function)
2
3 Not used (0 is set)
Terminal 4 input
selection (AU signal)
4
0: OFF
1: ON (Terminal 4 input is the main speed setting)
5 to 7 Not used (0 is set)
Command count 8 to 15 Used by the master to recognize the command response.
ESW
Up to frequency
(SU signal)
0
0: OFF
1: ON (Output frequency has reached the set frequency)
Overload alarm
(OL signal)
1
0: OFF
1: ON (Overload alarm occurrence)
2 to 7 Not used (0 is set)
Command count 8 to 15 Echo back of the command request.
Reserved 0 to 15 Not used (0 is set, 0 is returned)
Name Bit Definition