55
PPO TYPE SUPPORT SPECIFICATION
7
7.7.2 Parameter clear
Parameter clear can be performed from the master.
* Communication parameters (Pr. 117 to Pr. 124, Pr. 338 to Pr. 340, Pr. 343, Pr. 349, Pr. 549 to Pr. 551) are not cleared.
7.7.3 Operation mode read/write
Read/write of the operation mode can be performed from the master.
7.7.4 Set frequency read
The frequency set to the inverter can be read from the master.
* It is always displayed as frequency (Hz) regardless of the Pr. 37 setting.
PNU Item Data Definition Data Type
P2.2 Parameter clear 965AH AUs16
P2.3 All parameter clear 99AAH AUs16
P2.5 Parameter clear* 5A96H AUs16
P2.6 All parameter clear* AA99H AUs16
P2.8 Error history clear 0000H AUs16
PNU Item Data Definition Data Type
P3 Operation mode read/write
External operation mode:10H
PU operation mode:11H (Pr.79 = "6")
Network operation mode:14H
Us16
PNU Item Data Definition Data Type
P4.1 Set frequency (RAM) read* Set frequency (RAM) is read. AUs16
P4.2 Set frequency (EEPROM) read* Set frequency (EEPROM) is read. AUs16