Mitsumi electronic fr-a7np e Marine Battery User Manual


 
18
4 INVERTER SETTING
4.1 Parameter list
The following parameters are used for the communication option (FR-A7NP).
Set the values according to need.
*1 Parameters which can be displayed when the plug-in option (FR-A7NP) is mounted.
*2 The setting is apllied after inverter reset or at the next power-ON.
Parameter
Number
Name Setting Range
Minimum
Setting
Increments
Initial
Value
Refer to
page
79 Operation mode selection 0 to 4, 6, 7 1 0 20
338
Communication operation command
source
0, 1 1 0 23
339
Communication speed command
source
0, 1, 2 1 0 23
340 Communication startup mode selection 0, 1, 10 1 0 20
342
Communication EEPROM write
selection
0, 1 1 0 27
349
*1 Communication reset selection 0, 1 1 0 34
500
*1
Communication error execution waiting
time
0 to 999.8s 0.1s 0 28
501
*1
Communication error occurrence count
display
01029
502
*2
Stop mode selection at communication
error
0, 1, 2, 3 1 0 30
550
*2
NET mode operation command source
selection
0, 2, 9999 1 9999 23