Mitsumi electronic fr-a7np e Marine Battery User Manual


 
31
INVERTER SETTING
4
z Operation at error removal
Error Definition Pr. 502 Setting Operation Indication Fault Output
Communication line
0
Kept stopped
E.OP1 kept lit
Kept provided
1
2Restart
Normal indication Not provided
3 Continued
Communication
option itself
0, 3
Kept stopped E. 1 kept lit Kept provided
1, 2
CAUTION
Communication line error [E.OP1 (fault data: HA1)] is an error that occurs on the communication line.
Communication option error [E. 1 (fault data: HF1)] is an error that occurs in the communication circuit
inside the option.
Fault output indicates the fault output signal (ALM signal) and fault bit output.
When the fault output setting is active, fault records are stored in the faults history.
When the fault output setting is not active, fault record is overwritten to the faults history temporarily but
not stored.
After the error is removed, the fault indication is reset, changing the display back to normal, and the last
fault is displayed in the faults history.
•When the Pr. 502 setting is "1" or "2", the deceleration time is the normal deceleration time setting (e.g. Pr. 8,
Pr. 44, Pr. 45).
The acceleration time at a restart is the normal acceleration time setting (e.g. Pr. 7, Pr. 44).
•When the Pr. 502 setting is "2", the operation/speed command at a restart is the one given before the error
occurrence.
When a communication line error occurs at the Pr. 502 setting of "2", removing the error during deceleration
causes acceleration to restart at that point. (Acceleration is not restarted if the error is that of the option unit
itself.)