Mitsumi electronic fr-a7np e Marine Battery User Manual


 
73
PPO TYPE NON-SUPPORT SPECIFICATION
8
8.7 PROFIBUS PNU (Module type E5NP)
8.7.1 Real-time monitor area (IND=0000H (IND=00H, PP=00H))
The following items can be monitored from the master.
*1 Input terminal monitor details
Functions of each terminal are assigned using Pr.178 to Pr.184. (Refer to the inverter manual for details)
*2 Output terminal monitor details
Functions of each terminal are assigned using Pr.190 to Pr.192. (Refer to the inverter manual for details)
IND
PNU
Item
Increments
0000H 0H Output frequency 0.01Hz
0000H 1H Output current 0.01A
0000H 2H Output voltage 0.1V
0000H 4H Frequency setting 0.01Hz
0000H 6H Motor torque 0.1%
0000H 7H Converter output voltage 0.1V
0000H 8H Regenerative brake duty 0.1%
0000H 9H
Electronic thermal relay
function load factor
0.1%
0000H AH Output current peak value 0.01A
0000H BH
Converter output voltage
peak value
0.1V
0000H DH Output power 0.01kW
0000H EH Input terminal status *1
0000H FH Output terminal status
*2
0000H 13H Cumulative energization time 1h
0000H 16H Actual operation time 1h
0000H 17H Motor load factor 0.1%
0000H 18H Cumulative power 1kWh
0000H 33H PID set point 0.1%
0000H 34H PID measured value 0.1%
0000H 35H PID deviation 0.1%
0000H 3CH Motor thermal load factor 0.1%
0000H 3DH Inverter thermal load factor 0.1%
0000H 3EH Cumulative power 2 0.01kWh
IND
PNU
Item
Increments
b15 b0
—————RESMRS—RHRMRL——STRSTF
b15 b0
——————————ABCFU———RUN