79
PPO TYPE NON-SUPPORT SPECIFICATION
8
8.8.2 Pr. 900 to calibration parameter (frequency) area (IND=0300H (IND=03H,
PP=00H))
The following parameters can be set with IND=0300H.
*1 These parameters can be set for the Japanese version only.
*2 This parameter can be set for the NA, EC and CH versions only.
IND PNU
Parameter
Number
Name
Minimum
Setting
Increments
Setting Range
Decimal Hexadecimal
0300H 0H 900
FM terminal calibration *1
---
0300H 1H 901
AM terminal calibration *2
---
0300H 2H 902 Terminal 2 frequency setting bias frequency 0.01Hz 0 to 400 0 to 9C40
0300H 3H 903 Terminal 2 frequency setting gain frequency 0.01Hz 0 to 400 0 to 9C40
0300H 4H 904 Terminal 4 frequency setting bias frequency 0.01Hz 0 to 400 0 to 9C40
0300H 5H 905 Terminal 4 frequency setting gain frequency 0.01Hz 0 to 400 0 to 9C40
0300H 16H 922
Frequency setting voltage bias frequency (built-
in potentiometer) *1
0.01Hz 0 to 400 0 to 9C40
0300H 17H 923
Frequency setting voltage gain frequency (built-
in potentiometer) *1
0.01Hz 0 to 400 0 to 9C40