56
PPO TYPE SUPPORT SPECIFICATION
7.7.5 Terminal input read
Analog input values of terminals 2 and 4 can be read.
7.7.6 Inverter reset
The inverter can be reset from the master.
The inverter maintains the resetting status while reset is requested.
When Pr.75 = "1, 3, 15, 17", reset is enabled only during an inverter error.
7.7.7 Node address read
The node address of the inverter can be read.
PNU Item Data Definition Data Type
P5.1 Terminal 2 input value read Terminal 2 input value (%) is read. AUs16
P5.2 Terminal 4 input value read Terminal 4 input value (%) is read. AUs16
PNU Item Data Definition Data Type
P6 Inverter reset
The inverter is reset after the data was written
from the master.
Us16
PNU Item Data Definition Data Type
P918 Node address read Set node address is read. Us16