1.4 Specifications
Light Output:
Day Intensity..............................................270,000 ±25% effective candelas, single flash
Twilight Intensity..........................................20,000 ±25% effective candelas, single flash
Night Intensity......................................... 2,000 ±25% effective candelas, burst of flashes
Beam Pattern...............................................................120º horizontally, 3º min. vertically
max. intensity of 3% of peak at -10º
Flash Rate: Day......................................................................... 40 fpm - single white flash
Twilight.................................................................. 40 fpm - single white flash
Night................................................................40 fpm - white burst of flashes
Master/Slave Operation ........ Up to 24 slave SGF-60 Flashheads may share a common
sync and photocell circuit from one SGC-60 Master Controller.
Electrical Input:
Master Controller...................... 50 Watts. 120, 208, 240, 277, 380, 480 VAC. 50, 60Hz
Flashhead...............................500 Watts. 120, 208, 240, 277, 380, 480 VAC. 50, 60Hz
Requires specific voltage selector block and manual
change to transformer wiring for different AC voltages.
Mechanical Properties:
Flashhead
Weight...........................................................................................82 pounds (37.2 kg)
Dimensions............. 18.88"w (479.4mm) x 15.25"h (387.4mm) x 10.75"d (273.1mm)
Surface Area.......................................................................................1.89 square feet
Wind Load .............................................................. 100 pounds at 150 mph (240kph)
Master Controller
Weight ……………………………………………………… ........24 pounds (10.89 kg)
Dimensions .......................................14"w (356mm) x 12"h (305mm) x 6"d (152mm)
Operating Environment:
Operating Temperature..............................................................................-55ºC to +55ºC
Humidity.............................................................................................95% relative humidity
System Operating Status Indicators:
Flashhead, AC line power present ...............................................PWR ON Indicator DS1
Flashhead, high voltage present on capacitors ....................High Voltage Indicator DS1
(located on Trigger / High Voltage board)
Master Controller Indicators
Flashhead Status ..........................................................LEDs DS1 - DS24, red/green
Day Mode ..............................................................................................LED DS25 red
Twilight Mode ........................................................................................LED DS26 red
Night Mode ............................................................................................LED DS27 red