344
Communication operation and setting
List of calibration parameters
[Special monitor selection No.]
Refer to page 253 for details of the monitor description.
...........Specifications differ according to the date assembled. Refer to page 484 to check the SERIAL number.
*1 The setting depends on capacities. (55K or lower / 75K or higher)
*2 Input terminal monitor details (when the terminal is ON: 1, when the terminal is OFF: 0, —: undetermined value)
*3 Output terminal monitor details (when the terminal is ON: 1, when the terminal is OFF: 0, —: undetermined value)
*4 Details of option input terminal monitor 1 (input terminal status of FR-A7AX when the terminal is ON: 1, when the terminal is OFF: 0)-all terminals
are OFF when an option is not fitted
*5 Details of option input terminal monitor 2 (input terminal status of FR-A7AX when the terminal is ON: 1, when the terminal is OFF: 0, —:
undetermined value)-all terminals are OFF when an option is not fitted
*6 Details of option output terminal monitor (output terminal status of FR-A7AY/A7AR when the terminal is ON: 1, when the terminal is OFF: 0, —:
undetermined value)-all terminals are OFF when an option is not fitted
*7 When Pr. 37 = "1 to 9998" or Pr. 144 = "2 to 10, 102 to 110," the unit is an integral value (one increment). (Refer to page 251)
b15 b0
⎯⎯⎯⎯CS RES
STOP
MRS JOG RH RM RL RT AU STR STF
b15 b0
⎯⎯⎯⎯⎯⎯⎯⎯⎯ABC2 ABC1 FU OL IPF SU RUN
b15 b0
X15 X14 X13 X12 X11 X10 X9 X8 X7 X6 X5 X4 X3 X2 X1 X0
b15 b0
⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯DY
b15 b0
⎯⎯⎯⎯⎯⎯RA3RA2RA1Y6Y5Y4Y3Y2Y1Y0
Para
meter
Name
Instruction
code
Read
Write
Extended
C2
(902)
Terminal 2 frequency
setting bias frequency
5E DE 1
C3
(902)
Terminal 2 frequency
setting bias
5E DE 1
125
(903)
Terminal 2 frequency
setting gain frequency
5F DF 1
C4
(903)
Terminal 2 frequency
setting gain
5F DF 1
C5
(904)
Terminal 4 frequency
setting bias frequency
60 E0 1
C6
(904)
Terminal 4 frequency
setting bias
60 E0 1
126
(905)
Terminal 4 frequency
setting gain frequency
61 E1 1
C7
(905)
Terminal 4 frequency
setting gain
61 E1 1
C12
(917)
Terminal 1 bias
frequency (speed)
11 91 9
C13
(917)
Terminal 1 bias
frequency (speed)
11 91 9
C14
(918)
Terminal 1 gain
frequency (speed)
12 92 9
C15
(918)
Terminal 1 gain
(speed)
12 92 9
C16
(919)
Terminal 1 bias
command (torque/
magnetic flux)
13 93 9
C17
(919)
Terminal 1 bias
(torque/magnetic flux)
13 93 9
C18
(920)
Terminal 1 gain
command (torque/
magnetic flux)
14 94 9
C19
(920)
Terminal 1 gain
(torque/magnetic flux)
14 94 9
Para
meter
Name
Instruction
code
Read
Write
Extended
C38
(932)
Terminal 4 bias
command (torque/
magnetic flux)
20 A0 9
C39
(932)
Terminal 4 bias
(torque/magnetic flux)
20 A0 9
C40
(933)
Terminal 4 gain
command (torque/
magnetic flux)
21 A1 9
C41
(933)
Terminal 4 gain
(torque/magnetic flux)
21 A1 9
Para
meter
Name
Instruction
code
Read
Write
Extended
Data Description
Increments
H01
Output frequency/speed
*7
0.01Hz/1
H02 Output current
0.01A/
0.1A
*1
H03 Output voltage 0.1V
H05
Frequency setting value/
speed setting
*7
0.01Hz/1
H06 Running speed 1r/min
H07 Motor torque 0.1%
H08 Converter output voltage 0.1V
H09 Regenerative brake duty 0.1%
H0A
Electronic thermal relay
function load factor
0.1%
H0B
Output current peak
value
0.01A/
0.1A
*1
H0C
Converter output voltage
peak value
0.1V
H0D Input power
0.01kW/
0.1kW
*1
H0E Output power
0.01kW/
0.1kW
*1
H0F Input terminal status *2 ⎯
H10 Output terminal status
*3 ⎯
H11 Load meter
0.1%
H12 Motor excitation current
0.01A/
0.1A
*1
H13 Position pulse ⎯
H14
Cumulative energization
time
1h
H16 Orientation status ⎯
H17 Actual operation time 1h
H18 Motor load factor 0.1%
H19 Cumulative power 1kWh
H20 Torque command 0.1%
Data Description
Increments
H21 Torque current command 0.1%
H22 Motor output
0.01kW/
0.1kW
*1
H23 Feedback pulse ⎯
H2E
Motor temperature
1°C
H32 Power saving effect Variable
H33 Cumulative saving power Variable
H34 PID set point 0.1%
H35 PID measured value 0.1%
H36 PID deviation value 0.1%
H3A
Option input terminal
status1
*4
⎯
H3B
Option input terminal
status2
*5
⎯
H3C
Option output terminal
status
*6
⎯
Data Description
Increments