81
Parameter List
Parameter List
4
PARAMETERS
Current average
value monitor
555
Current average time 0.1 to 1.0s
0.1s 1s 390
556
Data output mask time 0.0 to 20s
0.1s 0s 390
557
Current average value monitor signal
output reference current
0 to 500/0 to 3600A *2 0.01/0.1A *2
Rated
inverter
current
390
⎯ 563
Energization time carrying-over times (0 to 65535)
1 0 253
⎯ 564
Operating time carrying-over times (0 to 65535)
1 0 253
Second motor
constants
569
Second motor speed control gain 0 to 200%, 9999
0.1% 9999 148
⎯
571
Holding time at a start 0.0 to 10.0s, 9999
0.1s 9999 175
⎯
574
Second motor online auto tuning 0, 1
1 0 199
PID control
575
Output interruption detection time 0 to 3600s, 9999
0.1s 1s 361
576 Output interruption detection level 0 to 400Hz 0.01Hz 0Hz 361
577
Output interruption cancel level 900 to 1100%
0.1% 1000% 361
⎯
611
Acceleration time at a restart 0 to 3600s, 9999
0.1s 5/15s *2 266
⎯
665
Regeneration avoidance frequency
gain
0 to 200% 0.1% 100% 383
⎯ 684
Tuning data unit switchover 0, 1
1 0 189
⎯
800 Control method selection 0 to 5, 9 to 12, 20 1 20
92,
148
⎯ 802 *6
Pre-excitation selection 0, 1
1 0 203
Torque command
803
Constant power range torque
characteristic selection
0, 1 1 0
100,
125
804
Torque command source selection 0 to 6
1 0 125
805 Torque command value (RAM) 600 to 1400% 1% 1000% 125
806
Torque command value
(RAM,EEPROM)
600 to 1400%
1% 1000% 125
Speed limit
807
Speed limit selection 0, 1, 2
1 0 127
808 Forward rotation speed limit 0 to 120Hz 0.01Hz 60Hz 127
809 Reverse rotation speed limit 0 to 120Hz, 9999 0.01Hz 9999 127
Torque limit
810
Torque limit input method selection 0, 1
1 0 100
811
Set resolution switchover 0, 1, 10, 11
1 0
100,
251
812 Torque limit level (regeneration) 0 to 400%, 9999 0.1% 9999 100
813 Torque limit level (3rd quadrant) 0 to 400%, 9999 0.1% 9999 100
814 Torque limit level (4th quadrant) 0 to 400%, 9999 0.1% 9999 100
815
Torque limit level 2 0 to 400%, 9999
0.1% 9999 100
816
Torque limit level during acceleration 0 to 400%, 9999
0.1% 9999 100
817
Torque limit level during deceleration 0 to 400%, 9999
0.1% 9999 100
Easy gain
tuning
818
Easy gain tuning response level
setting
1 to 15 1 2 105
819
Easy gain tuning selection 0 to 2
1 0 105
Func-
tion
Parameter
Name Setting Range
Minimum
Setting
Increments
Initial Value
Refer
to
Page
Customer
Setting