Mitsubishi Electronics MR-J3-B-RJ080W Life Jacket User Manual


 
APPENDIX
App. - 7
(2) Structure
The control circuit provide safe separation to the main circuit in the servo amplifier.
Direct drive motor
M
Cabinet
Servo
amplifier
Reinforced insulating type
24VDC
power
supply
Molded-case
circuit breaker
Magnetic
contactor
MCMCCB
(3) Environment
(a) Operate the servo amplifier at pollution degree 2 or 1 set forth in EN 60664-1. For this purpose, install
the servo amplifier in a cabinet which is protected against water, oil, carbon, dust, dirt, etc. (IP54).
(b) Environment
Item Environment
[ ]
(Note 2) 0 to 55
Operation
[
]
32 to 131
[ ]
20 to 65
(Note 1)
Ambient temperature
Storage,
Transportation
[
]
4 to 149
Ambient humidity
Operation,
Storage,
Transportation
90 RH or less
Operation,
Storage
1000m or less
Maximum altitude
Transportation 10000m or less
Note 1. Ambient temperature is the internal temperature of the cabinet.
2. The servo amplifier 200V 3.5kW or less can be mounted closely. In this case, keep the
ambient temperature within 0 to 45
(32 to 113 ) or use the servo amplifier with 75
or less of the effective load ratio.
(4) Power supply
(a) This servo amplifier can be supplied from star-connected supply with earthed neutral point of
overvoltage category
set forth in EN 60664-1. However, when using the neutral point of 400V system
for 1-phase supply, a reinforced insulating transformer is required in the power input section.
(b) For the interface power supply, use a 24VDC power supply with reinforced insulation on I/O terminals.