Mitsubishi Electronics MR-J3-B-RJ080W Life Jacket User Manual


 
5. PARAMETERS
5 - 6
5.4 Extension setting parameters (No.PC
)
5.4.1 Parameter list
POINT
For details of the parameters in which columns MR-J3- B is written, refer to the
MR-J3-
B Servo Amplifier Instruction Manual section 5.3.
The parameter whose symbol preceded by * can be validated with the following
conditions.
* : Turn off the power and then on again, or reset the controller after setting the
parameter.
Never change the parameters for the manufacturer setting.
No. Symbol Name Initial value Unit Reference
PC01 *ERZ Error excessive alarm level 3 rev MR-J3- B
PC02 MBR Electromagnetic brake sequence output 0 ms
PC03 *ENRS Encoder output pulses selection 0000h
PC04 0000h
PC05 0000h
PC06
For manufacturer setting
0000h
PC07 ZSP Zero speed 50 r/min MR-J3- B
PC08 For manufacturer setting 0
PC09 MOD1 Analog monitor 1 output 0000h
PC10 MOD2 Analog monitor 2 output 0001h
PC11 MO1 Analog monitor 1 offset 0 mV
PC12 MO2 Analog monitor 2 offset 0 mV
MR-J3-
B
PC13 For manufacturer setting 0
PC14 0
PC15 0
PC16
0000h
PC17 For manufacturer setting (Note) 0000h
PC18 For manufacturer setting 0000h
PC19
0000h
PC20 *COP7 Function selection C-7 0000h
PC21 *BPS Alarm history clear 0000h
MR-J3-
B
PC22 For manufacturer setting 0000h
PC23 0000h
PC24 0000h
PC25 0000h
PC26 0100h
PC27 0000h
PC28 0000h
PC29 0000h
PC30 0000h
PC31 0000h
PC32
0000h
Note. This parameter is "Function selection C-4" for the MR-J3- B servo amplifier, however the parameter is not available for the MR-J3-
B-RJ080W servo amplifier. If the setting is changed, a parameter error (37) occurs.