Dell 38XX Marine Radio User Manual


 
Retrieve the performance modeling data using PowerVault MD Storage Manager.
Performance modeling ends, but no data is available when one of the following conditions occurs:
You reboot the RAID controller module.
You make any changes to the SSD cache configuration.
The state of the SSD cache changes.
Start Storage Array Blink
Description
This command identifies a storage array by turning on the indicator LED for the storage array. Use the
stop storageArray blink command to turn off the indicator LED for the storage array.
Syntax
start storageArray blink
Parameters
None.
Start Storage Array Configuration Database Diagnostic
Description
This command runs a consistency check against a configuration database.
Syntax
start storageArray configDbDiagnostic
[sourceLocation=(disk | onboard)]
[diagnosticType = (fileSystem | mirror | contentCheck)]
[controller[(0 | 1)]]
Parameters
Parameter Description
sourceLocation
This parameter specifies the location of the
database.
disk indicates that data comes directly from
the database on the physical disk.
onboard indicates that data comes from the
RPA memory location
The default location is disk.
diagnosticType
The level of diagnostic testing that you want to run
on the database. You can run one of these levels of
testing:
390