Furuno FSV-84 SONAR User Manual


 
8-1
8. CUSTOMIZING THE EQUIPMENT
8.1 User Menu
You may program 10 often-used menu items to the user menu area in the menu.
The default user menu contains pulse length, Tx power, TVG near, TVG medium,
TVG far, AGC, 2
nd
AGC, echo average, color, and color response from the
H-SCAN SETTING menu.
User menu area
MENU QUIT
H-SCAN SETTING...
V-SCAN SETTING...
OTHERS...
TX PULSE LENGTH-H : 9
TX POWER-H : 9
TVG-NEAR-H : 0
TVG-MEDIUM-H : 0
TVG-FAR-H : 0
AGC-H : 0
2ND AGC-H : 0
ECHO AVERAGE : 0
COLOR-H : COLOR 1
COLOR RESPONSE-H : COLOR CURVE 3
Main menu (user menu)
8.1.1 Deleting items from user menu
The equipment is pre-programmed with ten user menu items. To change the
user menu you must first delete a menu item from the user menu which you do
not require.
1. Press the [MENU] key to open the main menu.
2. Select the item to delete.
3. Press and hold down the [MENU] key more than one second to show the
following dialog box.
DELETE REGISTRATION
SELECTED ITEM WILL BE
REMOVED FROM MAIN MENU.
NO
YES
Dialog box for deleting item from user (main) menu
4. Select YES and press the [MENU] key. The dialog box is then closed and the
selected item is deleted from the user menu.
5. Select QUIT at the top of the menu screen and press the [MENU] key to
close all menus.