Furuno FSV-84 SONAR User Manual


 
9. OTHERS MENU
9-3
TM DISPLAY RANGE: Selects how many times to expand the display range in
the true motion mode. 1.3R (R = Range) and 1.6R are available and the default
setting is 1.6R.
BEARING REF: Selects how to reference bearing for the vertical bearing marker.
The choices are ship’s heading (default) and North.
TILT LEVER: Chooses function of the TILT control.
TILT: Sets the tilt only.
TILT & V1: Sets the bearing of the vertical 1 display in the vertical display, and
sets the tilt in the horizontal display.
S AUTO OFF CENTER: Choose the train value in automatic own ship position
offset in the slant mode. The choices are 30°, 45°, 60° and OFF and the default
setting is 45°. AUTO TRAIN must be turned on to activate this function.
H-SLICE WIDTH: Chooses width of the history marker in the history display. The
choices are 1, 2, 4 and 8, 16 (default setting) and 32. The higher the number the
greater the width.
H-SLICE PICT ADVC: Determines how to advance the history display, by KP
SYNC (default setting) or ship’s speed.
NET COURSE MARK: Inscribes/deletes the net course mark. For further details
see “2.19 Net Course Mark”.
MANUAL DEGAUSS: In the default setting the screen is automatically
degaussed by the internal sensor when it detects stray magnetic fields on the
screen. If you want to degauss the screen manually select MANUAL DEGAUSS
and press the [MENU] key. Execute degaussing in intervals; consecutive
degaussing may result in color distortion.
AUTO DEGAUSS: Selects how to degauss the screen automatically.
OFF: Turns automatic degaussing off.
TIMER: Degausses at regular intervals.
GYRO: Using heading data from a heading sensor, degaussing occurs when
heading change exceeds a certain value.
INT SENSOR: Degaussing occurs when the sensor in the monitor unit detects
heading change which exceeds a certain value. This option is only operative on
the FURUNO monitor unit FSV-2400.
DIMMER: Adjusts backlighting of the control panel. The setting range is 1-10
and the default setting is 10 (maximum).
KEY BEEP VOLUME: Sets the volume of the beep which sounds for key
operation. The setting range is 0-7. “0” turns off the key beep.