Lucent Technologies 555-230-128 Life Jacket User Manual


 
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Compact Modular Cabinets
555-230-128
Issue 3
May 1998
Installation Completion and Cable Pinouts
Page 2-2Perform System Administration
2
Enable Alarm Origination to INADS
No External Modem Installed (or No Alarm Origination to INADS)
1. Enter change system-parameters maintenance and press Enter.
2. Enter n in the
Alarm Origination Activated to OSS Numbers
field and press
Enter.
3. For some software releases, enable
Cleared Alarm Notification
and
Restart Notification
before the submitting the form.
External Modem Installed
1. Enter change system-parameters maintenance and press Enter.
2. Enter y in the
Alarm Origination Activated to OSS Numbers
field and press
Enter.
3. For some software releases, enable
Cleared Alarm Notification
and
Restart Notification
before the submitting the form.
4. Be sure the system is part of the INADS database by calling the INADS
Database Administrator at the Technical Service Center (TSC). Verify that
INADS can dial into the system and that the system can dial out to INADS.
As part of the system registration process, the INADS Database
Administrator enables Alarm Origination and customer options.
NOTE:
When calling from a remote modem, you may need to disable error
correction to allow the modems to connect successfully. For
example, the AT&T Paradyne KeepInTouch
®
modem may require the
“AT\n0” command.
5. Log off and log back in.
Place a Test Call
1. From any telephone connected to a digital line circuit pack, call any
nearby telephone connected to an analog line circuit pack.
2. Verify that the dial tone, ringing pattern, and talk path are acceptable.
3. Place a call through the Central Office (outside call) to any nearby
telephone. Verify that the dial tone, ringing pattern, and talk path are
acceptable.