Lucent Technologies 555-230-128 Life Jacket User Manual


 
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Compact Modular Cabinets
555-230-128
Issue 3
May 1998
Install and Cable the Cabinets
Page 1-47Activate and Administer the System
1
Log into the System
1. Verify the screen displays: Login:
2. Type craft and press
Enter.
3. Type crftpw and press
Enter. The password does not display as it is typed.
The screen displays the system software version and the terminal types.
Terminal Type (513, 715, 4410, 4425, VT220): [513]
4. Enter the type of management terminal (such as 715) and press
Enter.
Check System Status
The system status may suggest problem areas. Refer to
DEFINITY Enterprise
Communications Server Release 6 Maintenance for R6csi
.
1. Type status system all-cabinets and press
Enter.
2. Verify the screen displays a service state of in for all appropriate areas.
Change Customer Options
Refer to
DEFINITY Enterprise Communications Server Release 6 Administration
and Feature Description
to view a sample screen.
The following features are part of the basic software package and do not require
activation. They default to y (yes) on the Optional Features form.
ARS/AAR Partitioning
Emergency Access to Attendant
Hospitality (Basic)
Service Observing
NOTE:
An init login is required to change customer options. Contact your regional
CSA (Customer Software Administrator) to perform this function.
1. Enter change system-parameters customer-options and press
Enter.
2. Using the customer order, enable the optional features purchased by the
customer (as shown by PEC codes on the customer order).
3. Press
Enter when finished to submit the form.
4. Logoff and then log back in to affect the customer option changes.