Lucent Technologies 555-230-128 Life Jacket User Manual


 
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Compact Modular Cabinets
555-230-128
Issue 3
May 1998
Install and Cable the Cabinets
Page 1-48Activate and Administer the System
1
Set Country Options
Some country options need to be set to turn off the red alarm LEDs.
1. Enter change system-parameters country options and press
Enter. A
screen similar to Screen 1-1
displays on the terminal. The cursor is set on
the Companding Mode field.
Screen 1-1. Typical System Parameters Country-Options Screen
2. The default (United States) companding mode is mu-Law. If the country
uses A-Law companding, type A-Law. Press
Enter when finished.
NOTE:
Other items eventually need to be entered on this screen, but this is
all that is needed to turn the red alarm LEDs off.
3. Set the country codes as needed in the following fields. Refer to Table 1-5
for the country codes. The United States country code (1) is shown in the
example above.
Digital Loss Plan:
Analog Ringing Cadence:
Analog Line Transmission: