Install and Cable the Cabinets
Page 1-70CAMA/E911 Installation
1
3. In the Group Name: field, enter the desired name.
4. In the TAC: field, enter the desired trunk access code.
5. In the Outgoing Display: field, enter y.
6. In the CESID I Digits Sent: field, enter the number directed by the
Central Office (CO) or the Public Safety Answering Point (PSAP).
7. Scroll to page 3 of the form.
Screen 1-5. Administrable Timers form (page 3)
8. On the Administrable Timers screen (page 3), you may need to adjust
these fields according to your CO. Scroll to page 5.
Page 3 of 11
TRUNK GROUP
ADMINISTRABLE TIMERS
Outgoing Disconnect (msec): 400
Cama Outgoing Dial Guard (msec): 75
Outgoing Glare Guard (msec): 1000
Cama Wink Start Time (msec): 5000
Outgoing End of Dial (sec): 1 Outgoing Seizure Response (sec): 4
Disconnect Signal Error (sec): 30