Install and Cable the Cabinets
Page 1-42Install and Set Up the Management Terminal
1
Install and Set Up the Management
Te rm i na l
To prevent unnecessary trouble tickets, do not enable the system alarms (Alarm
Origination feature) before completing all installation and administration
procedures.
1. Remove and retain the installation and usage instructions from the carton.
These instructions are needed to set up the terminal after installation. See
Figure 1-22
.
2. Locate the management terminal within 50 feet (15.2 m) of the system. It
may be necessary to reduce the maximum distance limitation if higher
gauge wire is used or if the capacitive load on the line is increased.
3. Connect the supplied 25-pin DTE management terminal cable (H600-426)
into the TERM connector (J3) on the Processor Interface Cable. See Tab l e
2-7 on page 2-11 for the pinout.
4. Connect an optional printer to either the management terminal (using the
supplied adapter cable) or to the DCE connector (J2) on the Processor
Interface Cable. See Table 2-7 on page 2-11
for the pinout of the DCE
connector.
5. Set the terminal power switch to the ON position when finished.