Install and Cable the Cabinets
Page 1-75CAMA/E911 Installation
1
Screen 1-11. CAMA Numbering Format form
33. In the CAMA Numbering - E911 Format screen (page 1), in System
CESID Default: field, enter your own system default and press
Enter.
This is the number outpulsed when the extension code is not found in the
CAMA Numbering table. See Screen 1-11
.
34. In the Ext Len, Ext Code, CESID, and Total Length fields, fill out to
your own CAMA numbering plan and press
Enter. Be sure to cover all
extensions.
35. At the prompt, type change cor <number> (the class of restriction (COR)
to be changed) and press
Enter. Change all CORs that are defined for
stations in order to remove any calling party restrictions for 911 calls.
Page 1 of 3
CAMA NUMBERING - E911 FORMAT
System CESID Default: 5241100______
Ext Ext Total Ext Ext Total
Len Code CESID Length Len Code CESID Length
4_ 101__ 5381234_____ 7_ __ _____ __________ __
4_ 1____ 555_________ 7_ __ _____ ___________ __
__ _____ ____________ __ __ ______ ___________ __
__ _____ ____________ __ __ ______ ___________ __
__ _____ ____________ __ __ ______ ___________ __
__ _____ ____________ __ __ ______ ___________ __
__ _____ ____________ __ __ ______ ___________ __