3 - 2
No. 99MBC034B
3.1.2 Specifying the gage resolution (for EV-16P and EV-16Z)
In order to connect a gage with a resolution that is not 1ยตm, the
counter must modify its resolution setting to that of the con-
nected gage.
(1) Press the Fn key repeatedly to display Parameter No. 12 and
the INPUT number of A.
[Display on the D-EV]
UNIT
+NG
GO
-NG
(2) Press the P.SET key to modify the setup value. (Refer to
section 3.1.5 List of parameters.)
(3) If more than one gage is connected, repeat steps (1) and (2)
to set the resolution of all gages while sequentially switch-
ing the INPUT number by pressing the Fn key.
(4) To complete the setting operation press the P.SET key
while holding down the Fn key.
If the EV-16Z is used, push in the spindle to pass through
the origin.
In order to continue the setup operation for other parameters
simply press the Fn key.
NOTE
In order to modify the existing resolution setting, either
press the Fn key repeatedly until the desired Parameter
No./INPUT number is displayed or exit from the parameter
mode and start the setup operation from the beginning.
3.1.3 Setting the axes to be used
If there are less than six gages connected, the setting of the num-
ber of available axes must be modified.
(1) Press the Fn key to display Parameter No.13.
[Display on the D-EV]
UNIT
+NG
GO
-NG
(2) Press the P.SET key to modify the setup value. (Refer to
section 3.1.5 List of parameters.)
NOTE If the setup is made as (Number of available axes) >
(Number of gages), an error display/output (Error40) will
result.
If the setup is made as (Number of available axes) <
(Number of gages), gages that have not been desig-
nated will be ignored.
For information refer to section 8.4 List of Error Outputs.