A SERVICE OF

logo

3 - 8
No. 99MBC034B
NOTE If the LOAD button is held down for more than 1 sec-
ond while the MODE button is held down, all param-
eters will be reset to the factory-set defaults.
During the parameter setup operation, the D-EV keys,
RS-232C output, and external signal input are dis-
abled.
3.2.4 List of parameters
* Factory-set default
Parameter name LED Setup content LED
8 7 6 5 4 3 2 1
Case of EV-16P or EV-16Z
Resolution of INPUT A
*1
10µm
Resolution of INPUT B
*1
5µm
Resolution of INPUT C
*1
1µm
*
Resolution of INPUT D
*1
0.5µm
Resolution of INPUT E
*1
Resolution of INPUT F
*1
Case of EV-16D
Gage type of INPUT A
INC (LGS series)
Gage type of INPUT B
Gage type of INPUT C
ABS (LGD series)
*
Gage type of INPUT D
Gage type of INPUT E
ABS ORG
Gage type of INPUT F
Counting direction of INPUT A
+ Counting
*
Counting direction of INPUT B
- Counting
Counting direction of INPUT C
If the spindle is pushed-in
Counting direction of INPUT D
Counting direction of INPUT E
Counting direction of INPUT F
Designation of available axis 1
*2
Axis designation 2 is valid
*
1 gage is connected
2 gages are connected
3 gages are connected
Designation of available axis 2
*2
Axis designation 1 is valid
*
4 gages are connected
5 gages are connected
6 gages are connected
*