I/O FUNCTION
This chapter describes the I/O function re-
lated to data input and output.
7.1 Overview of the I/O function
According to the I/O-type selection parameter, the I/O connector will
perform tolerance judgment output, BCD output, and segment output.
Each output can be performed in the NORMAL mode, calculation
mode, or high-speed mode as set by the I/O function selection param-
eter. (Refer to chapter 3 SETTING PARAMETERS.)
NOTE
The user must separately purchase the connection cable.
7.2 Connectors
Receptacle:
10236-52A2 (Manufacturer: 3M, half-pitch 36-pin, female)
Plug: 10136-3000VE (Manufacturer: 3M) or equivalent
Cover: 10336-52A0-008 (Manufacturer: 3M) or equivalent
7.3 Input/Output Circuit
7.3.1 Output circuit
Application:
Tolerance judgment output, NORMAL, and segment output
Operation:
Transistor turned ON at "L" (open-collector output)
Counter
TD62853 or
the equivalent
0.01uF
5k
+5V
74HC14 or
the equivalent
COM
Output
Reference
circuit of
external
equipment
Maximum output voltage: 24 V
Maximum output current: 10 mA
Maximum saturation voltage: 0.7 V
7.3.2 Input circuit
Application: P.SET, HOLD, SET
Operation: Input enabled at "L"
0.01uF
5k
+5V
Counter Reference
circuit of
external
equipment
COM
Input
Maximum input current: 1 mA
Input voltage (H): 4 - 24 V
Input voltage (L): 1 V max.
Use open-collector
output or relay
output, etc.