3 - 7
3 SETTING PARAMETERS
No. 99MBC034B
3.2.2 Setting the parameters
(1) Select the parameter name using the SEL. button and
MODE button. Each time the SEL. button is pressed, the
on/off pattern of LEDs No.3, 4, 5, and 6 will change. Each
time the MODE button is pressed, the on/off pattern of
LEDs No.7 and 8 will change.
[Parameter LED Indicator]
87
6
54
3
MODE
SEL.
87
6
54
3
MODE
SEL.
87
6
54
3
MODE
SEL.
6
54
3
SEL.
(2) Select the parameter value using the DATA button. Each
time the DATA button is pressed, the on/off pattern of LEDs
No.1 and 2 will change.
[Parameter LED Indicator]
21
DATA
21
DATA
21
DATA
21
DATA
(3) Accept the parameter value selected by pressing the LOAD
button. The next parameter for setup is automatically moved
to.
NOTE The modifications will not be reflected in the actual op-
eration unless they have been accepted.
(4) Repeat steps (1) to (3) to set the other required parameters.
(Refer to section 3.2.4 List of parameters.)
3.2.3 Parameter mode OFF
(1) Press the LOAD button while holding down the DATA but-
ton to set the parameter mode to OFF.
[Parameter LED Indicator]
87 6
54
321
LOAD MODE SEL. DATA
(2) The count value display will be restored. (after passing
through the origin, only EV-16Z restores the count value
display)