3 - 10
No. 99MBC034B
*1: If this parameter is modified, each zero point, preset value,
and tolerance value for CEL1 to CEL6 will all be cleared.
*2: For information about this function refer to TIP below.
*3: This is not modified even if an attempt is made to clear the
parameters. If the display unit is set to E, the UNIT LED
lights in green.
*4: Sets the CEL to be used for the calculation function. (This
function is valid only if Selection of I/O function is set to
Calculation mode.)
*5: If all CELs designated as the available axis are se-
lected, CELs to be used for calculation will be as shown in
the table below.
Setup value for designating CEL to be used for calculation
the available axes
6 1, 2, 3, 4, 5, 6
5 1, 2, 3, 4, 5
4 1, 2, 3, 4
3 1, 2, 3
2 or 1 1, 2
*6: For information about this function refer to chapter 7 I/O
FUNCTION.
*7: The output logic of the data section will vary depending on
the I/O type selection result. However, each logic of the
input signal, NORMAL, READY, START, and EXTEND
output remains fixed.
Tolerance judgment and segment output BCD output
The corresponding output terminal is 1=H, 0=L
L, and others are H.
The corresponding output terminal is 1=L, 0=H
H, and others are L.
*8: For information about this function refer to chapter 5 RS-
232C COMMUNICATION FUNCTION.
*9: The parameter modification will be made valid after reset-
ting the power.
*
10
:This function will output data from the RS-232C connector
if a HOLD signal is input through the I/O connector.
In the case of "
", all RS-232C commands will be inef-
fective.