Lowrance electronic LMF-200 Marine Instruments User Manual


 
33
Section 4: EP Configuration &
Calibration
To configure items connected to the LowranceNET network, press
MENU and select SYSTEM SETUP. Highlight B. DEVICES and press MENU,
which will open the Bus Devices list, a list of devices on the network.
Bus Devices works as the device manager for the bus, allowing you to
configure and unconfigure devices and set and reset critical values such
as alarms and calibration.
If you configure or reconfigure a sensor, you are assigning or
reassigning its configuration name in the LMF-200 to a different sensor
location on the boat.
NOTE:
The Suzuki Engine Interface, EP-10 Fuel Flow, EP-15 Fluid Level,
EP-35 Temperature Sensor and EP-50 Storage Device are the only
devices that can be configured through the Bus Devices list.
The following items can be configured, unconfigured or reconfigured:
Temperature (UnCfg Tmp), Fuel Flow (UnCfg FF) and Fluid Level
(UnCfg FL) sensors. When they are shown on the bus devices list as
UnCfg Tmp, UnCfg FF and the UnCfg FL, they are unconfigured.
You can have multiple Temperature sensors and Fluid Level Tanks,
but will have no more than three Fuel Flows to configure since the
LMF-200 supports a maximum of three engines on a vessel.
NOTE:
If you configure the desired sensors and are not satisfied with the
results, you may clear the configuration settings for each sensor
individually, by resetting values from the sensor's configuration
menu. Remember, ONLY the sensor you select from the Bus
Devices list will be set back to its defaults.
EP-35 Temperature Configuration
The EP-35 Temperature sensor has three configuration options: Inside,
Outisde and Water. An unconfigured temperature sensor will appear
on the Bus Devices list as UnCfg Temp.
To configure EP-35 Temp Sensor:
1. Press
MENU, use the UP and DOWN keys to select SYSTEM SETUP and
press
MENU.
2. Highlight
B. DEVICES and press MENU. After a few moments the Bus
Devices list, a list of devices on the network, will appear.