Lowrance electronic LMF-200 Marine Instruments User Manual


 
47
3. Highlight
PORT ENG and press MENU. Select CHANGE ENGINE and press
MENU,
which will open the Select Engine menu with up to three options
(Port, Center and Starboard), depending on your engine-tank
configuration.
4. Highlight STARBOARD and press MENU.
5. You will be taken back to the Bus Devices list, where the engine
interface you selected (formerly Port Eng) will now be displayed as
Stbd Eng. If the newly configured interface is not shown, refresh the
Bus Devices list.
Fuel Warning:
The Fuel Warning allows you to set a Low Level or High Level alarm
for each Suzuki Engine Interface on the network. A pop-up window will
appear if fuel rises above or falls below a threshold of your choosing.
1. Press
MENU, use the UP and DOWN keys to select SYSTEM SETUP and
press
MENU.
2. Highlight
B. DEVICES and press MENU. After a few moments, the Bus
Devices list will appear.
3. Select an engine interface and press
MENU.
4. Highlight
FUEL WRNG and press MENU. The Select Level menu will
appear with two options: Low Level and High Level.
5.
Select LOW LEVEL and press MENU, which will open the Level
Percentage window. It will be set to Off by default. To set the Fuel
Warning to High Level Repeat steps 1-4, then select
HIGH LEVEL from the
Select Level menu.
6. Use the UP and DOWN keys to set the desired fuel warning
percentage and press
MENU. You will be taken back to the Bus Devices
list.
NOTE:
To see fuel remaining information from the Suzuki Engine
Interface, you must change the Fuel Remaining Source to
Eng/FFlow. See page 28.
Reset:
The Reset command in the engine interface menu allows you to reset
configuration and calibration settings for a particular interface.
1. Press MENU, use the UP and DOWN keys to select SYSTEM SETUP and
press
MENU.
2. Highlight
B. DEVICES and press MENU. The Bus Devices list will
appear.