4-44
Programming
Lists of Commands
CALCulate1 Subsystem
:CALCulate1:DATA? Queries the uncorrected frequency-spectrum data of the input
signal.
S
:CALCulate1:TRANsform:FREQuency:POINts? Sets and queries the number of points in the data set. S
CALCulate2 Subsystem
:CALCulate2:DATA? Queries the corrected frequency-spectrum data of the input
signal.
S
:CALCulate2:PEXCursion Sets the peak excursion limit. I
:CALCulate2:POINts? Queries the number of points in the data set. I
:CALCulate2:PTHReshold Sets the peak threshold limit. I
:CALCulate2:PWAVerage[:STATe]? Places the instrument in the average-wavelength mode. Data
queries return the power-weighted average frequency,
wavelength, or wavenumber or total power.
I
:CALCulate2:WLIMit[:STATe] Limits input wavelength range of the Agilent 86120B. I
:CALCulate2:WLIMit:STARt:FREQuency Sets the starting frequency for the wavelength limit range. I
CALCulate2:WLIMit:STARt[:WAVelength] Sets the starting wavelength for the wavelength limit range. I
CALCulate2:WLIMit:STARt:WNUMber Sets the starting wavenumber for the wavelength limit range. I
:CALCulate2:WLIMit:STOP:FREQuency Sets the stopping frequency for the wavelength limit range. I
CALCulate2:WLIMit:STOP[:WAVelength] Sets the stopping wavelength for the wavelength limit range. I
CALCulate2:WLIMit:STOP:WNUMber Sets the stopping wavenumber for the wavelength limit range. I
CALCulate3 Subsystem
CALCulate3:ASNR:CLEar Resets and restarts the signal-to-noise ratio averaging I
CALCulate3:ASNR:COUNt Sets the number of measurements to average the signal-to-
noise ratio
I
CALCulate3:ASNR:[:STATe] Turns signal-to-noise ratio averaging mode on and off I
:CALCulate3:DATA? Queries the data resulting from delta, drift, and signal-to-noise
measurements.
S
:CALCulate3:DELTa:POWer[:STATe] Turns the delta power measurement mode on and off. I
:CALCulate3:DELTa:REFerence:FREQuency Selects the signal to be used as the reference for the DELTa
calculations.
I
:CALCulate3:DELTa:REFerence:POWer? Queries the power level of the reference signal. I
:CALCulate3:DELTa:REFerence[:WAVelength] Selects the signal to be used as the reference for the DELTa
calculations.
I
:CALCulate3:DELTa:REFerence:WNUMber Selects the signal to be used as the reference for the DELTa
calculations.
I
:CALCulate3:DELTa:WAVelength[:STATe] Turns the delta wavelength measurement mode on and off. I
Table 4-7. Programming Commands (2 of 4)
Command Description Code
Codes: S indicates a standard SCPI command. I indicates an instrument specific command.