5. PARAMETERS
5 - 11
Classification No. Symbol Name and function
Initial
value
Unit Setting range
PS17 LTSTS
Minute position detection method function selection
Used to set the response and the load to motor inertia moment ratio of
the minute position detection method.
To make the parameter valid, set parameter No.PS08 (Special function
selection 3) to "
4" (minute position detection method). (Refer to
section 4.2.5)
Low response
High response
Response of the minute position detection
method
00
Setting Response Setting Response
08
19
2A
3B
4C
5D
6E
7FMiddle response
Middle response
Setting
Load inertia
moment ratio
Setting
7 F 150 times or more70 times
08
19
2A
3B
4C
5D
6E
Less than 10 times 80 times
90 times10 times
100 times20 times
110 times30 times
120 times40 times
130 times50 times
140 times60 times
Load inertia
moment ratio
Selecting the load inertia moment ratio at the
direct drive motor, which decides the response of
the minute position detection method
0000h Refer to the
name and
function
column
PS18 IDLV
Minute position detection method identification signal amplitude
Used to set the identification signal amplitude for the minute position
detection method. To make the parameter valid, set parameter
No.PS08 (Special function selection 3) to "
4".
Identification signal is "100
" when "0000h" is set. (Refer to section
4.2.5)
0
0 to 100
PS19 0000h
PS20
For manufacturer setting
Do not change these values by any means.
0000h
PS21 0000h
PS22 0000h
Special setting parameters
PS23 0000h
PS24 0000h
PS25 0000h
PS26 0000h
PS27 0000h
PS28 0000h
PS29 0000h
PS30 0000h
PS31 0000h
PS32
0000h