97
9 Specifications
This chapter provides the power requirements, operating conditions (environmental requirements), physical
requirements, hardware specifications, and video resolutions of the HP Server tc3100.
The following tables provide the specifications required for normal operation of the HP Server tc3100.
NOTE The specifications and requirements for the power supply and environment can vary if
you install a mass storage device in the server that has more stringent environmental limits
than required for the HP Server. Ensure the operating environment for any mass storage
devices you intend to install are compatible with the server environmental requirements.
Power Supply Requirements
Parameter Characteristics
Input Type Wide-ranging, PFC
Input Voltage 100 to 127 VAC ± 10%, 50/60 Hz
200 to 240 VAC ± 10%, 50/60 Hz
Operating Current 100 VAC: 3.49 A, 345 W
120 VAC: 2.69 A, 339 W
200/208 VAC: 1.80 A, 329 W
220/230 VAC: 1.56 A, 325 W
In-rush Current 50 A peak, 240 VAC
Operating Power 320 W Continuous
Environment
Parameter Conditions
Temperature
Operating
Non-operating
5° to 35° C (41° to 95° F)
-40° to +65° C (-40° to +149° F)
Humidity
Operating
Non-operating
20% to 80% relative humidity,
non-condensing
5% to 95% relative humidity,
non-condensing
Altitude
Operating
Non-operating
-30 to 3,000 m (~ 10,000 ft)
-30 to 12,000 m (~ 40,000 ft)
Thermal Output
Maximum Operating
1662 BTU/hr
Acoustic Emissions Sound level (LpA): <40 dB(A)