Chapter 5 Error Messages
59
Code Description Problem/Solution
053X Hard Disk drive connection
problem
(This does not apply to tc3100)
(Error code #0530 is the primary
channel cable IDE1 and #0531 is
the secondary channel cable
IDE2)
POST has detected a hard disk drive on the second (slave) position on
the IDE cable, but no hard disk has been found on the first (master)
position.
To correct this:
1. If only one hard disk is connected on the cable, disconnect the
hard drive and use the other connector to re-connect the hard
drive into the first (master) position.
2. If two disks are connected on the cable, verify all data cables
and power cables are firmly connected for both hard disk drives.
3. If the error message appears just after a hard disk drive
installation, check for master/slave specific jumper
configurations in the hard disk drive installation manual.
4. If the problem persists, the hard disk drive may need to be
replaced. Contact your service representative.
0540 Hard Disk Controller resource
conflict
POST has detected an address space or IRQ resource conflict between
the integrated hard disk controller and an accessory board.
To correct this:
1. If the integrated hard disk controller is not needed, run the Setup
Utility to disable it (primary or secondary).
2. If the integrated hard disk controller is needed, the accessory
board's IRQ and address space must be reconfigured to use other
free resources. Refer to the accessory board installation manual
for information.
0600 Video Memory boot error
(This does not apply to tc3100)
The video memory size detected during POST is smaller than
previously detected.
To correct this:
1. If you have changed your video adapter, press F4 to
automatically validate the change.
2. If the problem persists, the system board may need to be
replaced. Contact your service representative.
0700 DIMM size boot error The system memory size detected during the POST is smaller than
previously detected. One or several DIMMs are either disconnected,
or have been replaced by smaller ones.
To correct this:
1. If some main DIMMs have just been removed or replaced by
smaller ones, press F4 to automatically validate the change.
2. If no DIMM has been removed or changed, ensure all DIMMs
are properly inserted in the slots.
3. If the problem persists, one of the DIMMs may need to be
replaced. Contact your service representative.
0712 DIMM installation error POST has detected an incorrectly installed DIMM or the failure of
one or more DIMMs.
To correct this:
1. If additional memory was just installed in your server, please
verify the installation conforms to the description in the User's
Guide.
2. If this error was reported when no additional memory was just
installed, restart the server.
3. If the error persists, contact your service representative.