HP (Hewlett-Packard) tc3100 Life Jacket User Manual


 
Chapter 5 Error Messages
61
Code Description Problem/Solution
0901 Integrated LAN enable error The system could not enable the integrated LAN.
To correct this:
1. Reset the Integrated LAN by powering off the HP Server.
2. Disconnect the power cord for 20 seconds.
3. Reconnect the power cord and power on the HP Server.
4. If the error appears upon restarting, update the system BIOS.
5. Insert the HP Navigator CD-ROM in the CD-ROM drive and
power-cycle your system.
This will initialize the flash utility on the HP Navigator CD-
ROM.
6. If the error persists, the system board may need to be replaced.
Contact your service representative.
0A00 Display refresh rate error The parameters returned by the display do not match the DDC
standard used by the server for automatic setup of ergonomic refresh
rates.
To correct this:
1. Disable the 'Plug & Play Display' feature in the Setup Utility to
avoid a blank or unreadable screen at power-up.
2. Use the Setup Utility to manually set the video refresh rates to
the highest ergonomic refresh rates supported by the display.
Refer to display monitor's User's Guide for specifications.
0B0x Missing Microcode Update Your system is missing the Microcode Update data block for the
microprocessor.
Your must correct this problem to avoid possible malfunction or
reliability problems.
To correct this:
1. Update your BIOS by running the flash utility from you
Navigator CD-ROM. To do this, insert the Navigator CD-ROM
in the CD-ROM drive and power-cycle your system.
2. If updating your BIOS does not clear this error, contact your
service representative.
0B1x Failed to load Microcode Update Your system has failed to load the Microcode Update data block for
the microprocessor.
Your must correct this problem to avoid possible malfunction or
reliability problems.
To correct this:
1. Update your BIOS by running the flash utility from you
Navigator CD-ROM. To do this, insert the Navigator CD-ROM
in the CD-ROM drive and power-cycle your system.
2. If updating your BIOS does not clear this error, contact your
service representative.
0B2x Defective Microcode Update The Microcode Update data block for the microprocessor is defective.
To correct this:
1. Update your BIOS by running the flash utility from you
Navigator CD-ROM. To do this, insert the Navigator CD-ROM
in the CD-ROM drive and power-cycle your system.
2. If updating your BIOS does not clear this error, contact your
service representative.