Mitsumi electronic FR-PU07/FR-PU07BB Marine Battery User Manual


 
27
Monitoring Function
2
2.1.4 Using
"READ"
to change the main monitor
Press to display the monitoring list while the main monitor is displayed.
Select a monitor from the monitoring list to change the main monitor.
Example: Select the output current peak value monitor.
*1 The selected monitor is not set as the first priority
monitor yet when only was pressed. Hence,
the selected monitor is erased from memory as
soon as the power is switched OFF or another
operation mode is selected. In this case, the item
must be selected again. When you press to
select the first priority screen, the selected item is
stored in memory.
*2 Pressing sets the selected "output current
peak" to be displayed in the first priority monitor
when switched to the monitoring mode from other
operation modes. To give first priority to another
monitor screen, press with that monitor screen
being displayed. (Refer to page 26)
1
Press .
The parameter unit is in the
monitoring mode.
2
Press .
The monitoring list appears.
3
Press / to move
the cursor to "Peak I".
Hold down
and press
or to shift one
screen.
4
Press . *1
The output current peak is
displayed.
5
Press . *2
The screen in step 4) is set as
the first priority monitor.
Subsequently press
to call another
monitor screen.
0.00A
--- STOP PU
READ
:
List
2 Current
3 Voltage
1 Frequency
4 Alarm His
10 Therm O/L
11 Peak I
9 Br.Duty %
12 DC Peak V
0.00A
--- STOP EXT
READ
:
List
REMARKS
· The setting can be also made from the function
menu. For details refer to page 53.
· When "Current monitor" or "Power monitor" is selected,
note that any current or power not more than 5% of the
rated inverter current cannot be detected and displayed.
Example:When a small motor is rotated with a large-
capacity inverter (a 0.4kW motor is used with a
55kW inverter), the power monitor keeps
displaying 0kW and is inoperative.