Setting and Changing the Parameter Values
2
2.3 Setting and Changing the Parameter Values
Using the FR-PU07/FR-PU07BB allows you to read the parameter of inverter or change the set value
easily. Refer to the inverter instruction manual for details of the parameters.
2.3.1 Specifying the parameter number to change the set value
Example: When changing 5s to 180s at the Pr. 8
Deceleration time setting
* If you entered an incorrect value, press to return
to the pre-entry state.
1
Press .
The frequency setting screen
appears, and operation mode
changes to PU operation mode.
(You need not press when
the parameter unit is already in
the PU operation mode.)
2
Press .
The parameter unit is in the
parameter setting mode.
3
Press .
Enter the desired parameter
number.
4
Press .
The present setting appears.
Freq Set
SET 0.00Hz
0~400Hz
SETTING MODE
0~9:Ser Pr.NO.
Select Oper
SETTING MODE
Pr.NO.
<READ>
8
8 Dec.T1
5.0S
0~3600
5
(1) Direct setting
Press .
*
Enter the desired value.
Or
(2)Step setting
Press .
Display "180" using .
6
Press .
The set value is changed.
7
Press to display the
next parameter.
8 Dec.T1
5.0S
0~3600
180S
180.0S
180.0S
8 Dec.T1
Completed
9 Set THM
2.55A
0~500