Mitsumi electronic FR-PU07/FR-PU07BB Marine Battery User Manual


 
36
Setting and Changing the Parameter Values
2.3.3 Selecting the parameter from parameter list to change the set value
Example: When changing 5s to 180s at the Pr. 8
Deceleration time setting
* If is pressed when an incorrect setting value is
input, the display returns to the list display "5".
1
Press .
The frequency setting screen
appears, and operation mode
changes to PU operation mode.
2
Press .
The parameter unit is in the
parameter setting mode.
3
Change the screen using
.
4
Select a parameter list.
Using , point the
cursor to "Pr.List".
5
Press .
Select the parameter list.
The list of the parameters can
be read appears.
Freq Set
SET 0.00Hz
0~400Hz
SETTING MODE
0~9:Ser Pr.NO.
Select Oper
2 Pr.List
3 User List
1 Appl.Grp
4 Param Copy
2 Pr.List
3 User List
1 Appl.Grp
4 Param Copy
1 Max.F1
2 Min.F1
0 Trq.Bst1
3 VFbaseF1
6
Select the parameter.
When moving the cursor
using and pressing
at "Dec.T1", the present
set value is called.
7
(1) Direct setting
Press .
*
Enter the desired value.
Or
(2)Step setting
Press .
Display "180" using .
8
Press .
The set value is changed.
9
Press to display the next parameter.
8 Dec.T1
5.0S
0~3600
8 Dec.T1
5.0S
0~3600
180S
180.0S
180.0S
8 Dec.T1
Completed