Note: Use Table 55 on page 194 to verify the proper replacement locations of your
E-DDMs.
1. Lift up on the handle and gently push the E-DDM CRU into the empty bay until
the hinge of the tray handle latches beneath the storage subsystem bezel, as
shown in Figure 30.
2. Push the tray handle down until the latch clicks into place.
3. Repeat step 1 and step 2 to replace additional E-DDMs.
Installing a Telco bezel
Complete the following step to install a bezel on a DS4700 Express Storage
Subsystem if the storage subsystem is shipped with one:
v Grasp the sides of the bezel and snap it onto the DS4700 Express chassis, as
shown in Figure 31 on page 54. The bezel is self-aligned in the recessed
opening in the front of the DS4700 Express chassis.
exp80018
Figure 30. Replacing an E-DDM
Chapter 2. Installing the storage subsystem 53