Utilities board
SMUC environmental monitoring
The following environmental conditions are monitored:
ASIC installation error sensing
FPGA configuration and status
Thermal sensing
Fan Sensing
Power failure sensing
48-V failure
48-V maintenance
Ambient air temperature sensing.
Power-on
Table 1 Environmental conditions monitored by the SMUC and power-
on circuit
Condition Type Action
ASIC Not Installed
OK
Environmental
error
Power not turned on, LED
indication
FPGA not OK Environmental
error
Power not turned on, LED
indication
48-V Fail Environmental
error
Power turned off, LED
indication
MIB power fail Environmental
error
Power turned off, LED
indication
Board over temp Environmental
error
Power off in one second,
LED indication interrupt
Fan not turning Environmental
error
Power off in one second,
LED indication interrupt
Ambient air hot Environmental
error
Power off in one second,
LED indication interrupt
Other power fail Environmental
error
Power off in one second,