M440FX Server System Product Guide
141
Changing SCSI Device ID Addresses
If you have a wide SCSI device ID conflict, you can resolve it by changing
the default ID addresses of the drives in the hot-docking bays. See the
jumper table on page 140.
See Figure 5-3.
1. Observe the warnings and cautions on page 3, “Safety Guidelines.”
2. Turn the system off with system power push-button on/off switch on
the front panel, and unplug each AC power cord from the power supply
or wall outlet.
3. Remove the right side cover as described in Chapter 4, “Working Inside
Your System.”
4. The jumpers are parallel with the backplane surface as shown in
Figure 5-3. Looking into the right side of the system, between the back
of the bay and the backplane, J10 is the top jumper and J9 is the next one
down. To remove a jumper, use a jumper removal tool.
5. To install a jumper, position it over the two pins for the desired setting
and press down firmly. Be careful not to bend the pins.
6. Replace the right side cover as described in Chapter 4, "Working Inside
Your System."
7. Plug the AC power cord of each power supply into a separate wall
outlet on a dedicated AC branch circuit to avoid overloading a single
branch circuit.