PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
WELDING PROBLEMS
Molten weld puddle appears exces-
sively "violent."
1. The Wire Type switch may be in
the wrong position for the elec-
trode wire being used.
2. The Peak Current or Back-
ground Setting may be too high.
Adjust for optimum welding per-
formance.
3. The Tailout may not be set cor-
rectly for the process. (STT II
Only)
1. The IGBT module may be faulty.
Check or replace.
2. The IGBT driver PC board may
be faulty.
3. The control PC board may be
faulty.