Lincoln Electric SVM129-B Marine Battery User Manual


 
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
INSTALLATION
A-2 A-2
INVERTEC STT
STANDARD VOLTAGE INPUT CURRENT AT RATED OUTPUT
208/230/460/3/60 HZ 32/30/16
200/220/380/415/440/3/50/60 HZ 33/30/18/17/16
TECHNICAL SPECIFICATIONS –Invertec STT & STT II (For Codes 11092 and BELOW)
INPUT- THREE PHASE ONLY
RATED OUTPUT
RECOMMENDED INPUT WIRE AND FUSE SIZES
INPUT VOLTAGE FUSE(SUPER LAG) INPUT AMPERE TYPE 75 C TYPE 75 C
AND FREQUENCY OR BREAKER RATING ON COPPER COPPER
SIZE NAMEPLATE SUPPLY WIRE GROUND WIRE
IN CONDUIT IN CONDUIT
AWG (IEC) SIZES AWG (IEC) SIZES
208/60 40 32
230/60 40 30
460/60 30 16
200/50/60 40 33
220/50/60 40 30 10 (6 mm
2
) 10 (6 mm
2
)
380/50/60 30 18
415/50/60 30 17
440/50/60 30 16
HEIGHT WIDTH DEPTH WEIGHT
23.2 in 13.2 in. 24.4 in. 100 lbs.
589 mm 336 mm 620 mm 46 kg
OUTPUT
DUTY CYCLE AMPS VOLTS AT RATED AMPS
60% Duty Cycle 225 29
100% Duty Cycle 200 28
CURRENT RANGE OPEN CIRCUIT VOLTAGE AUXILIARY POWER
Peak Current
1
0 - 450 Amps 85 VDC Maximum 115
2
VAC @ 4 Amps
Background 0 - 125 Amps 42 VAC @ 4 Amps
1
At low input voltages (below 208 VAC) and input voltages of 380 VAC through 415 VAC there may be a 15% reduction in Peak Current.
2
115 VAC not present on European Models.
PHYSICAL DIMENSIONS