Lincoln Electric SVM129-B Marine Battery User Manual


 
INSTALLATION
A-3 A-3
INVERTEC STT
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
STANDARD VOLTAGE INPUT CURRENT AT RATED OUTPUT
200/208/3/50/60 HZ 36/34
200/208/380/400/415/3/50/60 HZ 36/34/20/19/18
TECHNICAL SPECIFICATIONS –Invertec STT II (For Codes 11115 AND 11116)
INPUT- THREE PHASE ONLY
RATED OUTPUT
RECOMMENDED INPUT WIRE AND FUSE SIZES
INPUT VOLTAGE FUSE(SUPER LAG) INPUT AMPERE TYPE 75 C TYPE 75 C
AND FREQUENCY OR BREAKER RATING ON COPPER COPPER
SIZE NAMEPLATE SUPPLY WIRE GROUND WIRE
IN CONDUIT IN CONDUIT
AWG (IEC) SIZES AWG (IEC) SIZES
200/50/60 40 36
208/50/60 40 34
380/50/60 30 20 10 (6 mm
2
) 10 (6 mm
2
)
400/50/60 30 19
415/50/60 30 18
HEIGHT WIDTH DEPTH WEIGHT
23.2 in 13.2 in. 24.4 in. 100 lbs.
589 mm 336 mm 620 mm 46 kg
OUTPUT
DUTY CYCLE AMPS VOLTS AT RATED AMPS
60% Duty Cycle 225 29
100% Duty Cycle 200 28
CURRENT RANGE OPEN CIRCUIT VOLTAGE AUXILIARY POWER
Peak Current 0 - 450 Amps 88 VDC Maximum 115
1
VAC @ 4 Amps
Background 0 - 125 Amps 42 VAC @ 4 Amps
1
115 VAC not present on European Models.
PHYSICAL DIMENSIONS